A window fitted with 24 small loudspeakers reduced recorded transport noise by 7.51 to 10.14 decibels inside a laboratory room, researchers reported in Scientific Reports on July 9, 2020. The sliding window stayed open. For buildings that rely on open windows for ventilation, the useful qualification is the frequency range: the test signals were limited to 100–1,000 hertz, and the system achieved almost no active reduction below 300 hertz. [S2][S3]

The experiment used a one-meter-square, two-panel sliding window in a plywood room measuring 2.1 meters on each side. With the window opened and its frames and security grille accounted for, the clear opening measured 0.45 by 0.93 meters. The 24 speakers, each 4.5 centimeters in diameter, sat on the grille. A separate loudspeaker two meters outside replayed the noise. This was a controlled room experiment using real recordings, not a trial in an occupied building beside moving traffic. [S2]

Bhan Lam and colleagues used recordings of highway traffic, elevated trains and aircraft fly-bys captured at a Singapore high-rise apartment building. For the room-wide result, they averaged sound energy over seven observation microphones rather than reporting only the quiet spot next to one sensor. Within the restricted test band, the supplement reports reductions of 8.67 decibels for traffic, 10.14 for trains and 7.51 for aircraft. Those differences matter to a building operator: the noise source's frequency content changes what the same equipment can achieve. [S2][S3]

The small speakers were a practical compromise. They reduced visual obstruction and interference with airflow, but the authors attribute the weak low-frequency performance to that choice. Active control was also restricted between 300 and 500 hertz. Train noise benefited from a strong reduction around 700 hertz; aircraft noise left a prominent residual near 500 hertz. The experiment therefore does not support treating the headline reduction as a guarantee against low-pitched aircraft or transformer noise. [S2]

Closing the window still blocked more sound in the actual experiment. It beat active control with the window open by 2.22 to 6.39 decibels in the room-average measurements, at the cost of closing the ventilation opening. The paper's more favorable numerical comparisons describe different conditions. Its supplement models a normally incident plane wave and idealized line sources; for active control to outperform full glazing through about 1,000 hertz, that model required at least 75% glazing. That prediction is not evidence that the tested, fully opened sliding window was quieter than a shut one. [S2][S3]

The operating setup also traded adaptability for fewer sensors. The team first trained the controller with band-limited white noise, then stored the filters that determined the speakers' anti-noise output. During operation, one reference microphone supplied the incoming-noise signal, while the error microphones used during training were removed. Without those error sensors, the authors warn, the system cannot monitor or correct misadjustment. Methods to select, train and switch filters without excessive computing demands remained research work. [S2]

Source documents

  1. Active control of broadband sound through the open aperture of a full-sized domestic windowhttps://www.nature.com/articles/s41598-020-66563-z
  2. Supplementary Material: Active control of broadband sound through the open aperture of a full-sized domestic windowhttps://media.springernature.com/original/springer-static/esm/art%3A10.1038%2Fs41598-020-66563-z/MediaObjects/41598_2020_66563_MOESM1_ESM.docx