A National Institute of Standards and Technology study posted on August 20, 2019, shows how motion capture can shorten data collection for robot calibration without delivering submillimeter absolute positioning. In its KUKA-arm experiment, the researchers collected each motion-capture dataset within 20 minutes; collecting the laser-tracker optimization dataset took about 3.5 hours. For manufacturers, faster measurement helps only if the remaining error fits the job. [S2]

NIST researchers Karl Van Wyk, Joe Falco and Geraldine Cheok adjusted the robot’s joint zero-offsets—constants that correct how joint positions translate into the calculated location of the tool. Their method used measurements from an external sensor and Bayesian inference to estimate those corrections and their uncertainty. It was tested on a seven-degree-of-freedom KUKA arm, initially calibrated by visually aligning marks at its joints. The authors designed the method for calibration where the robot is installed, rather than requiring a precision marker plate at its base. [S2]

The collection-time comparison has a specific cause. The OptiTrack Trio motion-capture system followed an infrared reflector automatically, while the API T3 laser tracker needed partly manual help to reacquire its marker after losing the beam. The robot ran at 30 percent of its speed setting and paused for three seconds to settle at each configuration. The reported times therefore describe these measurements and settings, not the duration of an entire calibration job or a guaranteed reduction in production downtime. [S2]

The validation test exposes the accuracy limit. After applying the joint corrections derived from motion-capture data, the team tested 32 separate tool poses spanning 156 joint configurations. Mean relative errors were 0.558 millimeters as measured by motion capture and 0.492 millimeters by the laser tracker. But mean absolute errors after coordinate registration were 1.838 and 1.509 millimeters, respectively. Relative error describes the spread when different joint configurations aim for the same pose; it is not the distance from the intended location. [S2]

The study’s fourfold improvement across the whole workspace was a model-based estimate, not a measurement at every point. The authors also reported that their method did not bring average absolute positioning error below one millimeter. They attributed most of the remaining error to factors beyond joint zero-offsets, including other geometric parameters and structural deflection. Further refining the same offsets would therefore offer limited improvement on this arm. [S2]

The researchers describe motion capture as a lower-cost alternative to the benchmark laser tracker, but provide no purchase-price comparison or factory payback calculation. Both sensors were installed for the experiment; their method does not require buying both for practical use. It is evidence about a calibration option, not a priced business case. [S2]

Calibration is also distinct from locating the workpiece in the robot’s coordinate system. NIST’s December 2017 report on point-based registration describes that separate mapping problem and tests a correction method in peg-in-hole experiments. Success required the peg to go fully into the hole with less than 17 newtons of force; jamming during withdrawal still counted as failure. That threshold belonged to the earlier experiment, not a general operating limit or a validation of the 2019 calibration method. A positioning-error figure alone would miss the withdrawal failures that the earlier test counted. [S4]

Source documents

  1. Efficiently Improving and Quantifying Robot Accuracy In Situ — arXiv v1https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=925569
  2. NISTIR 8198: Improving Automated Insertion Applications by Restoring Rigid-Body Condition in Point-Based Registrationhttps://nvlpubs.nist.gov/nistpubs/ir/2017/NIST.IR.8198.pdf